Length (L)
100 mmDrill hole diameter (d0)
8 mmHole in fixture (df)
8.5 mmFixture thickness (tfix,1)
50 mmNominal setting depth (hnom,1)
50 mmEffective setting depth (hef,2)
50 mmDrill hole depth (h1,1)
60 mmMinimum base material thickness (hmin,1)
100 mmEmbedment depth (hnom) | Load direction | Load type | Load value | ETA | |
|---|---|---|---|---|---|
| Cracked concrete, C12/15 | 50 mm | NRec | 1,8 kN | ||
| Cracked concrete, C12/15 | 50 mm | VRec | 1,3 kN | ||
| Cracked concrete, C20/25 | 50 mm | NRec | 2,6 kN | ||
| Cracked concrete, C20/25 | 50 mm | VRec | 0,8 kN | ||
| Non cracked concrete, C12/15 | 50 mm | NRec | 1,8 kN | ||
| Non cracked concrete, C12/15 | 50 mm | VRec | 1,3 kN | ||
| Non cracked concrete, C20/25 | 50 mm | NRec | 2,6 kN | ||
| Non cracked concrete, C20/25 | 50 mm | VRec | 0,8 kN | ||
| Solid clay brick, fb ≥ 20,5 N/mm2 | 50 mm | NRec | 0,6 kN | ||
| Solid clay brick, fb ≥ 20,5 N/mm2 | 50 mm | VRec | 0,6 kN | ||
| Solid sand-lime brick, fb ≥ 20 N/mm2 | 50 mm | NRec | 0,7 kN | ||
| Solid sand-lime brick, fb ≥ 20 N/mm2 | 50 mm | VRec | 0,7 kN |